ES-IGW-E1 · All-in-One Controller

Sensor inputs, relay control and Modbus in one industrial gateway

The ES-IGW-E1 reads sensors directly on its analog and digital inputs, controls equipment through its relay outputs, and talks to meters and controllers over Modbus, RS485, RS232 and CAN bus. You configure it from a web dashboard.

En-Stream ES-IGW-E1 All-in-One Controller gateway
Specifications

Technical specifications

Ethernet2x (Internet + Modbus TCP)
Serial1x RS485, 1x RS232
FieldbusCAN bus
Analog inputs4x (0–20 mA / 0–10 V, 16-bit)
Digital inputs8x (12–24 V)
Relay outputs8x, for actuator control
Power24V DC / 10A
ConfigurationWeb dashboard
Use cases

What the ES-IGW-E1 is used for

  1. Direct sensor monitoring

    Wire temperature, pressure, flow or humidity transmitters with 0–20 mA or 0–10 V outputs straight into its four 16-bit analog inputs.

  2. Status and alarm signals

    Pick up running, fault or mains-failure signals on eight 12–24 V digital inputs.

  3. Equipment control

    Switch actuators such as pumps, fans or alarm sounders through eight relay outputs.

  4. Mixed equipment on one gateway

    Combine Modbus TCP and RTU, RS232 and CAN bus devices with direct sensors, at sites where equipment comes from many vendors.

Industries

Where it's used

  • Pharmaceuticals

    HVAC, cleanroom utilities and compressed air monitoring for compliance and uptime.

  • Textiles

    Machine health on looms and spinning lines, plus energy per production unit.

  • Food & Beverage

    Boiler, chiller and compressed-air monitoring, plus production line uptime.

  • Chemicals & Fertilizer

    Pump, motor and utility monitoring for continuous processes.

  • Data Centers & Telecom

    Mains, generator, fuel and DC power monitoring, plus panel alarms, across distributed sites.

  • Cold Storage

    Temperature monitoring, compressor health and instant alerts on power loss.

  • Commercial Buildings

    Multi-meter energy tracking, plus HVAC and generator costs per floor or tenant.

  • Packaging

    Line uptime, motor and VFD health, and compressed air leak detection.

Compare

Compare the gateways

FeatureES-IGW-B1ES-IGW-E1 (This gateway)
Best forBest for collecting data from existing meters and controllers.Best for sites that need direct sensor inputs and equipment control.
Ethernet2x (Internet + Modbus TCP)2x (Internet + Modbus TCP)
Serial1x RS4851x RS485, 1x RS232
FieldbusNot includedCAN bus
Analog inputsNot included4x (0–20 mA / 0–10 V, 16-bit)
Digital inputsNot included8x (12–24 V)
Relay outputsNot included8x, for actuator control
Power5V DC / 3A24V DC / 10A
ConfigurationWeb dashboardWeb dashboard
FAQ

ES-IGW-E1 FAQ

Which sensors can I connect?

Any sensor with a 0–20 mA or 0–10 V output on the four 16-bit analog inputs, and 12–24 V signals on the eight digital inputs.

Can it control equipment?

Yes. Eight relay outputs switch actuators such as pumps, fans or alarm sounders.

What power does it need?

24V DC at 10A.

Can it also read meters and PLCs like the ES-IGW-B1?

Yes. It has the same two Ethernet ports (internet and Modbus TCP) and RS485, plus RS232 and CAN bus.