The ES-IGW-B1 collects data from energy meters, drives and controllers over Modbus TCP and RS485, and sends it to the En-Stream platform. You configure it from a web dashboard.

| Ethernet | 2x (Internet + Modbus TCP) |
|---|---|
| Serial | 1x RS485 |
| Power | 5V DC / 3A |
| Configuration | Web dashboard |
Read a chain of energy meters on one RS485 line and see consumption by department, line or building.
Pull data from PLCs and VFDs that speak Modbus TCP or RTU, without replacing them.
Install a gateway at each site and see every site on the same platform.
Start with meters on the B1, and add an ES-IGW-E1 where a site later needs direct sensors or equipment control.
HVAC, cleanroom utilities and compressed air monitoring for compliance and uptime.
Machine health on looms and spinning lines, plus energy per production unit.
Boiler, chiller and compressed-air monitoring, plus production line uptime.
Pump, motor and utility monitoring for continuous processes.
Mains, generator, fuel and DC power monitoring, plus panel alarms, across distributed sites.
Temperature monitoring, compressor health and instant alerts on power loss.
Multi-meter energy tracking, plus HVAC and generator costs per floor or tenant.
Line uptime, motor and VFD health, and compressed air leak detection.
| Feature | ES-IGW-B1 (This gateway) | ES-IGW-E1 |
|---|---|---|
| Best for | Best for collecting data from existing meters and controllers. | Best for sites that need direct sensor inputs and equipment control. |
| Ethernet | 2x (Internet + Modbus TCP) | 2x (Internet + Modbus TCP) |
| Serial | 1x RS485 | 1x RS485, 1x RS232 |
| Fieldbus | Not included | CAN bus |
| Analog inputs | Not included | 4x (0–20 mA / 0–10 V, 16-bit) |
| Digital inputs | Not included | 8x (12–24 V) |
| Relay outputs | Not included | 8x, for actuator control |
| Power | 5V DC / 3A | 24V DC / 10A |
| Configuration | Web dashboard | Web dashboard |
Devices that speak Modbus TCP over Ethernet or Modbus RTU over RS485, such as energy meters, VFDs and PLCs.
From a web dashboard.
5V DC at 3A.
When you need direct sensor inputs (0–20 mA / 0–10 V analog or 12–24 V digital), CAN bus, RS232 or relay outputs to control equipment. The ES-IGW-B1 reads data from existing meters and controllers.

What drives the cost of an industrial energy management system in Pakistan, what to ask suppliers, and how to start small without overspending.
Book a 30-minute demo and see how En-Stream connects to the meters, machines and generators you already run.