Data Concentrator
The ES-IGW-B1 reads PLCs, VFDs and energy meters over Modbus TCP and RS485.
- Ethernet
- 2x (Internet + Modbus TCP)
- Serial
- 1x RS485
- Power
- 5V DC / 3A
- Configuration
- Web dashboard
Packaging lines run fast, and a stopped motor or a drop in air pressure stops everything behind it. En-Stream watches motors, drives and compressed air live, so your team catches problems before the line stops.

Brief stoppages from a tripped drive or a jam rarely get recorded, but together they cut a shift's output.
Pneumatic machines depend on compressed air, and leaks waste energy around the clock without anyone hearing them.
Motors and VFDs on conveyors, fillers and wrappers show signs before they fail, but nobody is watching the data.
En-Stream reads these from your existing meters, drives and controllers, or from sensors wired to a gateway.
Running and stop signals from each machine, from its PLC or a gateway's digital inputs.
Current, speed and fault data from the drives on conveyors, fillers, sealers and wrappers.
Flow, pressure and compressor power, so leaks and abnormal demand show up early.
kW and kWh from energy meters on each line or large machine.
Grid, generator and solar, live, so you see which source carries the load.


Alarms on drive faults, a stopped machine or low air pressure, sent the moment they happen.


Compressed air, boiler gas and fuel next to electricity, for the whole plant.


A view per line for operators, and a plant view for management.

The ES-IGW-B1 reads PLCs, VFDs and energy meters over Modbus TCP and RS485.

Add the ES-IGW-E1 for direct pressure and flow transmitters, running signals on its digital inputs, or relay outputs.
Yes. En-Stream tracks compressed air flow, pressure and compressor power next to electricity, so leaks and abnormal demand show up as soon as they start.
En-Stream watches readings from motors, VFDs, pumps and other equipment. Its AI spots trends that come before a failure and alerts your team early, so maintenance can be planned instead of reacting to breakdowns.
Yes. En-Stream is vendor-agnostic. It reads PLCs, VFDs and meters over Modbus TCP and RTU, RS485 and RS232, and sensors over analog and digital inputs.
No. Gateways connect to the meters, drives and controllers you already have. Most sites take 1–3 days on site, and larger plants are installed in phases, so production never stops.

A practical guide for plant and energy managers. Find where power is wasted, use cheaper sources at the right time, and keep the savings with monitoring.
Book a 30-minute demo and see how En-Stream connects to the meters, machines and generators you already run.
HVAC, cleanroom utilities and compressed air monitoring for compliance and uptime.
Machine health on looms and spinning lines, plus energy per production unit.
Boiler, chiller and compressed-air monitoring, plus production line uptime.
Pump, motor and utility monitoring for continuous processes.
Mains, generator, fuel and DC power monitoring, plus panel alarms, across distributed sites.
Temperature monitoring, compressor health and instant alerts on power loss.
Multi-meter energy tracking, plus HVAC and generator costs per floor or tenant.