Data Centers & Telecom

Power, fuel and site monitoring for data centers and telecom sites

Every site depends on mains, generators, DC power and fuel, often with nobody there to watch them. En-Stream brings ATS readings, breaker status, DC current, fuel levels and panel alarms from every location into one live view, and alerts your team the moment something changes.

Rows of server cabinets in a data center hall
The problem

Why distributed sites are hard to run

  1. Outages are found after the fact

    A tripped breaker, a failed changeover or a generator that won't start is often discovered only when the site goes down.

  2. Fuel goes missing

    Diesel is bought for every generator, but without tank levels it's hard to tell consumption from refills, and refills from pilferage.

  3. Panels are opened unseen

    Doors on power and DC panels are opened, and smoke or heat builds up, without anyone knowing until the next visit.

  4. Every site visit costs time

    Checking meters, tanks and panels in person across many sites is slow and expensive, and still leaves gaps between visits.

What to measure

Readings that matter at data centers and telecom sites

En-Stream reads these from ATS panels, meters and DC panels, or from sensors and contacts wired to a gateway.

  • Mains and generator ATS

    Line voltages, phase currents, power per phase, frequency and energy, for both the utility supply and the generator.

  • Breaker and changeover status

    Which incomers and load breakers are on, off or tripped, and whether the site is running on mains or generator.

  • Fuel tanks

    Level, litres available, consumption, refills and pilferage, for underground tanks and generator tanks.

  • DC power

    Current on every shunt across your DC panels, so the DC load is visible panel by panel.

  • Panel conditions

    Front and back door status, smoke alarms, temperature and humidity for each AC and DC panel.

  • Trends over time

    Current, kW, kVA and voltage graphs, to spot load growth and supply problems early.

Dashboards

Dashboards network and site teams use

  • Custom dashboard exampleCustom dashboard example

    Custom Dashboards

    ATS readings, panel status, fuel tanks and DC shunts, each on its own screen, laid out the way your sites are wired.

  • Alarms and alerts dashboardAlarms and alerts dashboard

    Alarms & Alerts

    Alarms on breaker trips, mains failure, low fuel, a drop in tank level, open doors, smoke or high temperature, sent the moment they happen.

  • Energy flow · liveSimulated data
    Solar4.3 kWGrid5.5 kWGenerator2.5 kWFacilityTotal load 12.3 kW

    Energy Flow

    Grid, generator and solar feeding each site, live, and which source carries the load.

Hardware

Gateways for data centers and telecom sites

En-Stream ES-IGW-B1 Data Concentrator gateway
ES-IGW-B1

Data Concentrator

The ES-IGW-B1 reads ATS panels, energy meters and other Modbus devices over Modbus TCP and RS485.

Ethernet
2x (Internet + Modbus TCP)
Serial
1x RS485
Power
5V DC / 3A
Configuration
Web dashboard
Full specs
En-Stream ES-IGW-E1 All-in-One Controller gateway
ES-IGW-E1

All-in-One Controller

The ES-IGW-E1 adds direct inputs: door contacts, smoke alarms and breaker status on its digital inputs, and temperature, humidity and fuel level sensors on its 0–20 mA / 0–10 V inputs.

Ethernet
2x (Internet + Modbus TCP)
Serial
1x RS485, 1x RS232
Fieldbus
CAN bus
Analog inputs
4x (0–20 mA / 0–10 V, 16-bit)
Digital inputs
8x (12–24 V)
Relay outputs
8x, for actuator control
Power
24V DC / 10A
Configuration
Web dashboard
Full specs
FAQ

Data center and telecom monitoring FAQ

Can En-Stream detect fuel theft?

Yes. Tank monitoring tracks the level, consumption and refills of each tank and flags pilferage, so fuel that leaves the tank without being used shows up straight away.

Can we see whether a site is on mains or generator?

Yes. ATS readings and breaker status show which source is feeding the site, and alarms tell your team when it changes over or a breaker trips.

Can En-Stream monitor DC power?

Yes. It reads the current on each DC shunt, panel by panel, alongside the AC readings from the ATS.

Can we see all our sites in one place?

Yes. Every site reports to the same platform, and remote access lets your team open any site's dashboards from any device.

How does data get from a remote site to the platform?

Gateways send data, encrypted, to the platform over Ethernet, Wi-Fi or GSM.

Live demo

See En-Stream on your site

Book a 30-minute demo and see how En-Stream connects to the meters, machines and generators you already run.

More industries

Energy and machine monitoring for other industries

  • Pharmaceuticals

    HVAC, cleanroom utilities and compressed air monitoring for compliance and uptime.

  • Textiles

    Machine health on looms and spinning lines, plus energy per production unit.

  • Food & Beverage

    Boiler, chiller and compressed-air monitoring, plus production line uptime.

  • Chemicals & Fertilizer

    Pump, motor and utility monitoring for continuous processes.

  • Cold Storage

    Temperature monitoring, compressor health and instant alerts on power loss.

  • Commercial Buildings

    Multi-meter energy tracking, plus HVAC and generator costs per floor or tenant.

  • Packaging

    Line uptime, motor and VFD health, and compressed air leak detection.